Q
Can you show me details of multi-level collection device for wax collection (heated tubes from graphite box to collector also ?)
A
Yes, DMF will offer multi-level collection device for wax collection (heated tubes from graphite box to collector.
-
Q
The hot water temperature regulation/ heater is also included in control unit of furnace or separate ?
A
The hot water temperature regulation is set separately, while the heater is included in control unit of furnace.
-
Q
Min and max negative pressure for Ar dewaxing ?
A
Negative Pressure for Ar Dewaxing Max= 35mbar Min=5mbar
-
Q
Max Ar pressure for sintering with Argon atmosphere (without diffusion pump) ? 1000 mbar pressure OK ?
A
∴Max Ar pressure for sintering with Ar (without diffusion pump) =40mbar ∴1000 mbar pressure is availabe but will increase at least 10% equipment cost.
-
Q
If sintering in Ar atmosphere, all the furnace is also under Ar atmosphere at same pressure ?
A
It can be regarded as the same pressure although the pressure near the vacuum access is a bit lower which can be ignored.
-
Q
Floor footprint / Overall dimensions of furnace ?
A
DMF will offer the layput as per requirment in details.
-
Q
Requirements (cooling water/compressed air....) ?
A
Cooling Water: 0.1~0.25MPa, diameter 2", 6~8M3/h
-
Q
Kwalità ta 'Ar meħtieġa?
A
Purità tal-Argon: 99.999%
-
Q
Fuq in-naħa tax-xiri/loġistika, tista' tgħidilna x'inhu l-Kodiċi HS għat-tagħmir (forsi se jkun aktar minn wieħed)? Irridu li din l-informazzjoni tiċċekkja x'inhuma d-dazji potenzjali applikati għall-importazzjoni tal-magna.
A
Kodiċi HS (Kodiċi Armonizzat b'10 Diġiti): 8514109000
-
Q
Tista' tgħidli dwar il-proċedura u l-prekawzjonijiet meta nużaw il-gass H2 bit-tisħin? Ikun utli li tgħidilna d-differenza mill-każ tal-gass N2.
A
Iva, jekk jogħġbok iċċekkja l-ktieb manwali kif xieraq. Huwa miktub kemm bl-Ingliż kif ukoll biċ-Ċiniż